Table 4: Spirometry. FEV1, FVC and FEV1/FVC among demolition workers, insulators, carpenters and hospital porters. Adjusted odds ratios* (OR) with 95% confidence interval (CI).
Demolition workers | Insulators | Carpenters | Hospital porters | Total | |||||
N = 141 | N = 149 | N = 296 | N = 313 | N = 899 | |||||
n (%) | OR [95% CI] | n (%) | OR [95% CI] | n (%) | OR [95% CI] | n (%) | OR | n (%) | |
FEV1/FVC < 0.7 | 29 (21) | 1.1 [0.6-1.9] | 27 (18) | 0.9 [0.5-1.5] | 37 (13) | 0.8 [0.5-1.3] | 55 (18) | 1 | 148 (17) |
FEV1 < LLN | 24 (17) | 1.3 [0.7-2.3] | 16 (11) | 0.8 [0.4-1.6] | 14 (5) | 0.5 [0.2-0.9] | 37 (12) | 1 | 91 (10) |
FVC < LLN | 9 (6) | 1.1 [0.5-2.6] | 7 (5) | 0.7 [0.3-1.6] | 2 (1) | 0.1 [0.0-0.6] | 21 (7) | 1 | 39 (4) |
*OR is adjusted for smoking status, age group and BMI