Flash Visual Evoked Potential versus Pattern Visual Evoked Potential in the Diagnosis of Strabismic Amblyopia
Amany Abd El-Fattah El-Shazly, Walid Mohamed Abd E, Raouf El-Zawahry and Noha Ezzat Elsherbiny
Article Type: Research Article | First Published: August 01, 2016
We included 60 children with unilateral amblyopia, their age ranging between 4 and 10 years. Thirty age and sex matched healthy children were included as a control group. The included children underwent complete ophthalmologic evaluation with focus on subjective monocular visual acuity, cycloplegic refractions, slit-lamp examination, fundus examination, orthoptic evaluation, stereoacuity, worth 4-dot test....
Open Access DOI:10.23937/2378-346X/1410060
The Accuracy of Automated Angle Closure Screening Software
Anita Manassakorn, Chonlada Theeraworn, Pished Bunnun, Sirichai Nithi-Uthai, Rangsarit Vanijjirattikhan, Kittipong Ekkachai, Waree Kongprawechnon, Toshiaki Kondo, Direk Patikulsila and Kanokvate Tungpimolrut
Article Type: Research Article | First Published: July 19, 2016
Peripheral anterior chamber angle images of 27 eyes were taken by slit lamp biomicroscope and analyzed by automated software. The software selected region of interest and applied a light reflection extraction to detect corneal thickness (CT) and peripheral anterior chamber depth (PACD). Three observers manually counted CT (CTm) and PACD (PACDm) pixels and compared with the CT and PACD pixel counts that were obtained by the software (CTa and PACDa)....
Open Access DOI:10.23937/2378-346X/1410059
Relation of Pupil Size and Cataract Surgery using PupilX
Annekatrin Rickmann, Maria Waizel, Peter Szurman and Karl T Boden
Article Type: Original Article | First Published: July 08, 2016
Pupil size of healthy study participants was measured with infrared-video PupilX pupillometer (MEye Tech GmbH) at 5 different illumination levels (0, 0.5, 4, 32 and 250 lux) before and after cataract surgery. Measurements were performed by the same investigator. 90 images were recorded during a measurement period of 3 seconds. The absolute linear camera resolution was approximately 20 pixels per mm....
Open Access DOI:10.23937/2378-346X/1410058
A Novel Osmoprotectant Tear Substitute for the Treatment of Dry Eye Disease
Giuseppe Giannaccare, Michela Fresina and Piera Versura
Article Type: Research Article | First Published: July 05, 2016
Thirty patients (24 women, 6 men, median age 45.5 yrs) were enrolled. Inclusion criteria were: age ≥ 18 years, good general health, ocular discomfort symptoms for over three months, Ocular Surface Disease Index (OSDI) score ranging from 18 to 36, Schirmer test > 10 mm/5 min, Tear Film Break Up Time (TBUT) < 10 sec, corneal fluorescein staining ranging from 1 to 7 according to NEI level. Patients were administered three times daily for a two-month period with Isomar Eyes Plus, a hypotonic s...