Table 1: Criteria for diagnosis and grading of stenosis in B-mode and color Doppler ultrasound.

 

< 75% Stenosis

75% Stenosis

Occlusion

B-mode US

No plaque or thrombus

Plaque or thrombus < 50% of luminal diameter

Plaque or thrombus ≥ 50% of luminal diameter

Plaque or thrombus with no visible lumen

Color Doppler US

Color filled > 50% of luminal diameter

Color filled < 50% of luminal diameter and color aliasing

No color filled