Table 3: Diagnostic accuracy.

Diagnosticaccuracy (95% CI)

Sensitivity

Specificity

PPV

NPV

Accuracy

Geriatrician-performed PoCUS

100 (2.5 to 100)

96.4 (81.7 to 99.9)

50.0 (12.8 to 87.3)

100 (100 to 100)

96.5 (82.2 to 99.9

 

 

True positive

False positive

False negative

True negative

Geriatrician-performed PoCUS

1

1

0

27

Diagnostic accuracy- Data are presented as sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for geriatrician-performed PoCUS. Lastly, the number of true positive, false positive, false negative and true negative cases are presented.