Removal of Extruded Ex-Press Miniature Glaucoma Device in a Case with Ahmed Glaucoma Valve: A Case Report

Sinan Bilgin1* and Ozcan Kayikcioglu2


1Department of Ophthalmology, Faculty of Medicine, Sifa University, Turkey
2Department of Ophthalmology, Faculty of Medicine, Celal Bayar University, Turkey


*Corresponding author: Sinan Bilgin, Department of Ophthalmology, Faculty of Medicine, Sifa University, 103/1 sk. No:3 35290 Goztepe, Izmir 35290 Turkey, Tel: +905054321725, Fax: +902324442002, E-mail: drsinanbilgin@yahoo.com
Int J Ophthalmol Clin Res, IJOCR-3-047, (Volume 3, Issue 1), Case Report; ISSN: 2378-346X
Received: November 19, 2015 | Accepted: January 29, 2016 | Published: January 31, 2016
Citation: Bilgin S, Kayikcioglu O (2016) Removal of Extruded Ex-Press Miniature Glaucoma Device in a Case with Ahmed Glaucoma Valve: A Case Report. Int J Ophthalmol Clin Res 3:047. 10.23937/2378-346X/1410047
Copyright: © 2016 Bilgin S, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.



Abstract

Here, we report our experience with explanation of ex - press miniature glaucoma device which extruded due to conjunctival erosion in a case with Ahmed glaucoma valve implant. After explanation of the shunt, opening-insertion site on the cornea was covered with conjunctival autograft. Although transient hypotony and limited choroidal detachtment were observed in the first two days, no complications related to failure of Ahmed glaucoma valve occurred. Because of an increasing number of patients with ex-press miniature glaucoma device, complications are observed more frequently. Surgeons might consider similar approach under such conditions.


Keywords

Ahmed glaucoma valve, Ex-Press tube shunt, Tube exposure management


Introduction

Over the years, the ex-press miniature glaucoma device have gained increasing popularity as an alternative to trabeculectomy [1-4]. However, implantation of them underneath the conjunctiva resulted in various complications including conjunctival erosion, extrusion, hypotony, suprachoroidal hemorrhage, sub-conjunctival scar tissue formation and other adverse effects [2,5,6]. We herein reported our experience with explanation of ex-press miniature glaucoma device which extruded due to conjunctival erosion in a case with an Ahmed glaucoma valve implant in the same eye.


Case Report

A 70-years-old man with advanced open angle glaucoma in both eyes has been followed up in our clinic for longer than 5 years. On the last examination, visual acuity was finger counting at 4 meter in the right eye, and 0.2 in the left eye. Intra ocular pressure (IOP) was 14 mm Hg in right eye and 16 mm Hg in the left eye. There was an ex-press miniature glaucoma device at 12 o'clock position which had been implanted about ten years ago in the left eye. In addition, conjunctival erosion and implant exposure were observed (Figure 1A). During 3 months follow-up, Seidel test was negative because of obstruction of the external plate lumen with fibrin plug. Furthermore, left eye had received Ahmed glaucoma valve implant placed in the superior temporal area, and diode laser cyclophotocoagulation. We decided to remove ex-press device for reducing risk of long term postoperative endophthalmitis.


.
Figure 1: Exposition of Ex-press shunt (A), Demonstration of conjunctival autograft placed on remaining aperture (B), Limited choroidal detachment (C), Smooth conjunctival surface and scatrisation at last visit (D). View Figure 1



.



In our surgical technique we entered the anterior chamber with a 20G MVR knife adjacent with the implant and turned express shunt sideways, its spur towards the stab incision. Then it was easy to pull ex-press shunt away. The incision site was sutured with a 10/0 nylon but was leaky due to round opening of the shunt in limbal area. It was not possible to pull superior conjunctiva over the incision so we decided to remove an autograft from inferior conjonctiva which was placed and sutured with 10/0 nylon sutures (Figure 1B).

During the postoperative follow-up, transient hypotony(ranged from 4 to 10 mm Hg for ten days) and limited choroidal detachtment were observed (Figure 1C). On the last examination, satisfactory graft healing was observed (Figure 1D). Seidel test was negative and inraocular pressure was 14 mmHg. Choroidal detachment regressed, and also no complication related to failure of Ahmed glaucoma valve was observed.


Conclusions

The initial results following these glaucoma devices performed under conjunctival flaps were disappointing due to early postoperative hypotony and late device erosions/extrusions. Changing subconjunctival approach towards implantation of it under the scleral flep has yielded encouraging results.

On the other hand, implant extrusion and conjunctival erosion following both surgical approach may still be encountered. Also a case of endophthalmitis occurring shortly after ex-press implantation under a partial-thickness scleral flap was reported by Cherof et al. They performed pars plana vitrectomy with injection of intravitreal antibiotics, however, the corneal infiltrate enlarged and the back plate of the device became partially exposed. Clinical improvement was not achieved until the device was removed and the original surgical site was reinforced with a patch graft. Authors recommend that clinicians should consider early device removal to achieve resolution of infection [7]. In this case, although Seidel test was negative we prefered to remove ex-press tube due to increased risk of endophthalmitis. In a case series, by Joshua et al. exposed ex-press miniature glaucoma device were removed and to cover the sclerostomy, a scleral graft and conjuntival flap were used. In 5 eyes, the visual acuity worsened following the device removal. Intraocular pressure ranged from 8 to 17 mm Hg. Any other complication was not observed [8].

In this case, the patient had an advanced glaucoma and had multiple operations even including diode laser cyclophotocoagulation which made us more cautious. We thought that use of a conjunctival flap or graft might help to avoid potential complications including wound leakage, hypotony, infection, epithelial downgrowth. So we covered corneal round aperture using conjunctival autograft. Although, hypotony and limited choroidal detachtment were observed at early postoperative period, we did not observe any complication related to Ahmed glaucoma valve. Following graft healing, detachment regressed and hypotony improved. Furthermore, IOP has now been under control without antiglaucoma medication.

In conclusion, because of an increasing number of patients with ex-press miniature glaucoma devices, complications may be observed more frequently which may necessitate device removal with minimal operative trauma with similar approaches as described in this case.


Statement of Ethics

This case report description followed the Helsinki Declaration criteria, and written informed consent was obtained from the patient for publication of this article and any accompanying images. The Institutional Review Board and Ethics Committee ruled that approval was not required for this study.


Disclosure Statement

Each author warrants that he/she has no commercial associations that might pose a conflict of interest in connection with the submitted article.


References
  1. Dahan E, Carmichael TR (2005) Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma 14: 98-102.

  2. Traverso CE, De Feo F, Messas-Kaplan A, Denis P, Levartovsky S, et al. (2005) Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification. Br J Ophthalmol 89: 425-429.

  3. Chan JE, Netland PA (2015) Ex-press Glaucoma Filtration Device: efficacy, safety, and predictability. Med Devices (Auckl) 8: 381-388.

  4. Wamsley S, Moster MR, Rai S, Alvim HS, Fontanarosa J (2004) Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study. Am J Ophthalmol 138: 1049-1051.

  5. Stewart RM, Diamond JG, Ashmore ED, Ayyala RS (2005) Complications following ex-press glaucoma shunt implantation. Am J Ophthalmol 140: 340-341.

  6. Tavolato M, Babighian S, Galan A (2006) Spontaneous extrusion of a stainless steel glaucoma drainage implant (Ex-PRESS). Eur J Ophthalmol 16: 753-755.

  7. Cherof AM, SooHoo JR, Kahook MY, Seibold LK (2015) Endophthalmitis with Corneal Infiltrate After EX-PRESS Glaucoma Drainage Device Implantation. J Glaucoma.

  8. Stein JD, Herndon LW, Brent Bond J, Challa P (2007) Exposure of Ex-press Miniature Glaucoma Devices: case series and technique for tube shunt removal. J Glaucoma 16: 704-706.

Go to top
International Journal of Anesthetics and Anesthesiology (ISSN: 2377-4630)
International Journal of Blood Research and Disorders   (ISSN: 2469-5696)
International Journal of Brain Disorders and Treatment (ISSN: 2469-5866)
International Journal of Cancer and Clinical Research (ISSN: 2378-3419)
International Journal of Clinical Cardiology (ISSN: 2469-5696)
Journal of Clinical Gastroenterology and Treatment (ISSN: 2469-584X)
Clinical Medical Reviews and Case Reports (ISSN: 2378-3656)
Journal of Dermatology Research and Therapy (ISSN: 2469-5750)
International Journal of Diabetes and Clinical Research (ISSN: 2377-3634)
Journal of Family Medicine and Disease Prevention (ISSN: 2469-5793)
Journal of Genetics and Genome Research (ISSN: 2378-3648)
Journal of Geriatric Medicine and Gerontology (ISSN: 2469-5858)
International Journal of Immunology and Immunotherapy (ISSN: 2378-3672)
International Journal of Medical Nano Research (ISSN: 2378-3664)
International Journal of Neurology and Neurotherapy (ISSN: 2378-3001)
International Archives of Nursing and Health Care (ISSN: 2469-5823)
International Journal of Ophthalmology and Clinical Research (ISSN: 2378-346X)
International Journal of Oral and Dental Health (ISSN: 2469-5734)
International Journal of Pathology and Clinical Research (ISSN: 2469-5807)
International Journal of Pediatric Research (ISSN: 2469-5769)
International Journal of Respiratory and Pulmonary Medicine (ISSN: 2378-3516)
Journal of Rheumatic Diseases and Treatment (ISSN: 2469-5726)
International Journal of Sports and Exercise Medicine (ISSN: 2469-5718)
International Journal of Stem Cell Research & Therapy (ISSN: 2469-570X)
International Journal of Surgery Research and Practice (ISSN: 2378-3397)
Trauma Cases and Reviews (ISSN: 2469-5777)
International Archives of Urology and Complications (ISSN: 2469-5742)
International Journal of Virology and AIDS (ISSN: 2469-567X)
More Journals

Contact Us

ClinMed International Library | Science Resource Online LLC
3511 Silverside Road, Suite 105, Wilmington, DE 19810, USA
Email: contact@clinmedlib.org
 

Feedback

Get Email alerts
 
Creative Commons License
Open Access
by ClinMed International Library is licensed under a Creative Commons Attribution 4.0 International License based on a work at https://clinmedjournals.org/.
Copyright © 2017 ClinMed International Library. All Rights Reserved.