Join Us | Latest Articles | Contact

Journal Home


Editorial Board


Archive


Submit to this journal


Current issue

International Journal of Ophthalmology and Clinical Research





DOI: 10.23937/2378-346X/1410050



Intraoperative Corneal Incision Evaluation with Trypan Blue Technique

Ozcan Kayikcioglu1, Sinan Bilgin2* and Mahmut Oguz Ulusoy1


1Department of Ophthalmology, Faculty of Medicine, Celal Bayar University, Manisa 45000, Turkey
2Department of Ophthalmology, Faculty of Medicine, Sifa University, Izmir 35290, Turkey


*Corresponding author: Sinan Bilgin, Department of Ophthalmology, Faculty of Medicine, Sifa University, 103/1 sk. No:3 35290 Goztepe, Izmir, Turkey, Tel: +905054321725, Fax: +902324442002, E-mail: drsinanbilgin@yahoo.com
Int J Ophthalmol Clin Res, IJOCR-3-050, (Volume 3, Issue 2), Research Article; ISSN: 2378-346X
Received: January 12, 2016 | Accepted: May 10, 2016 | Published: May 13, 2016
Citation: Kayikcioglu O, Bilgin S, Ulusoy MO (2016) Intraoperative Corneal Incision Evaluation with Trypan Blue Technique. Int J Ophthalmol Clin Res 3:050. 10.23937/2378-346X/1410050
Copyright: © 2016 Kayikcioglu O, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.



Abstract

In this report, we aimed to determine wound leakage by instillation of trypan blue onto main incision and side port incisions during phacoemulsification surgery with clear corneal incision technique. Thirty-four eyes with cataract of 34 patients, who were operated by phacoemulsification method were included in the study. Incision points were hydrated by balanced saline solution and leakage was controlled at the end of the surgery. Trypan test revealed minor leakage in 23 out of 34 eyes (67.6%). All of these leakages occurred at the side-port incisions. Trypan blue technique based on the logic of Seidel test seems to be an effective and simple method for demonstrating unnoticed wound leakages.


Keywords

Corneal incision, Phacoemulsification, Trypan blue, Wound leakage


Introduction

Phacoemulsification surgery is a method which requires small incision and leads to lesser wound site problems compared to surgical procedures with larger incisions [1]. In this method, side insertions are hydrated, the main insertion hole heals spontaneously following clear corneal incision technique. Wound site leakage is a known risk factor for early postoperative complications including shallow anterior chamber and acute endophthalmitis [2]. These leakages are mostly checked by classical methods intraoperatively and the surgery is finalized in case of non-leakage. The aim of our study was to determine leakages by trypan blue instillation onto main and side insertion holes after phacoemulsification surgery.


Patients and Methods

The observational case series included 34 eyes with cataract of 34 patients. All patients underwent routine phacoemulsification with clear corneal incision and all had a posterior chamber intraocular lens (PCIOL) implantation with injection through the main incision. In this procedure, side port incisions were made by 20-gauge MVR/stiletto and main incisions were made by 3.0 mm keratome. All of the incisions were hydrated by balanced saline solution at the end of the procedure. Anterior chamber stability was controlled visually. Then incisions were controlled for leakage with the help of a cotton swab. When a leakage was observed, corneal stroma were hydrated until the leakage stopped. When there was no leakage observed, trypan blue was instilled onto main and side insertion holes for final leakage control. A leakage was defined as a clear line in blue background clearance of the dye on aqueous surface (Figure 1). After the test, trypan blue was irrigated from surface by balanced saline solution.


.
Figure 1: This intraoperative photograph reveals leakage of aques from the side port incision, visible on application of trypan blue. Clear fluid is distinctly seen streaming into a pool of trypan blue. View Figure 1



.



Results

Of the studied eyes, 13 were right eye and 21 were left eye. Trypan test revealed leakage in 23 of the 34 eyes (67.6%). All leakages occurred from the side-port incision sites. Leakage was determined from both incision points in 9 eyes, from nasal side incisions in 6 eyes, and from temporal side incisions in 8 eyes. None of the patients showed leakage from the main incision sites. Considering the total wound sites, leakage occurred from 26 of the 102 (25.4%) wound sites. Trypan blue did not enter anterior chamber in any of the patients.


Discussion

Wound site leakage is the leading etiological factor for development of toxic anterior segment syndrome (TASS), and of endophthalmitis, the most serious complication of cataract surgery [2]. It has been shown in many studies, surface liquids may enter into globe because of intraocular pressure alterations [3,4]. Srinirvasan et al. reported anterior chamber contamination in 46% of the patients [5].

Wound integrity may vary as a function of intraocular pressure. The clear corneal wound remains self-sealing if the intraocular pressure exceeds a certain threshold, exerting an outward force on the cornea thereby sealing the wound [6]. Whether leakage occurs passively through wound leaks or actively via the squeezing action of the upper lid on the globe or both is not known with any certainly. Also not only may these wound leaks serve as a portal of entry for pathogens and toxic substances but the resulting reduced intraocular pressure may also drop below the threshold enabling gaping of the unhealed wound [6].

Chee et al. in their study, used 5% povidone iodine in order to evaluate wound leakage and suggested that this method was effective for determining wound leakage. In addition, they stated that leakage is high when the corneal main incision is short, and wound site stability is high when the tunnel is long and incision is square shaped [7]. In our study, a 2 mm main insertion hole parallel to iris plane was made by using 3 mm keratome in all patients by the same surgeon. None of the patients showed leakage from the main insertion holes.

Use of cellulose sponge is another frequently practiced method, but this is a contact technique and the product is required solely for the purpose of testing wound integrity. Use of trypan blue to aid visualization of wound leakage is, in principle, similar to the Seidel’s test, which employs a strip of fluorescein, applied to the wound. Both test are positive when the dye is washed away from the wound by egress of aqueous. This technique has a few advantages over the use of fluorescence. For instance, we use trypan blue routinely for capsula staining so there is a source of trypan blue ready to be used. Secondly blue contrast shows leakage readily without use of cobalt blue light for floresence.

In conclusion, this observational series suggest that small wound leakage, especially from the side-port incision, may occur in a large number of eyes and remain asymptomatic. Although these micro leaks are of not high significance in routine cases but in case of high risk for infection as in blepharitis, surgeon should be more careful and spend more time on wound construction and sealing. Trypan blue technique based on the logic of Seidel test seems to be an effective and simple method for demonstrating unnoticed wound leakages, and this non- touch technique can be used to detect even minor wound leakage more readily and more distinctly.


Statement of Ethics

This case report description followed the Helsinki Declaration criteria, and written informed consent was obtained from the patient for publication of this article and any accompanying images. The Institutional Review Board and Ethics Committee ruled that approval was not required for this study.


Disclosure Statement

Each author warrants that he/she has no commercial associations that might pose a conflict of interest in connection with the submitted article.


References
  1. Uusitalo RJ, Ruusuvaara P, Jarvinen E, Raivio I, Krootila K (1993) Early rehabilitation after small incision cataract surgery. Refract Corneal Surg 9: 67-70.

  2. Lundström M (2006) Endophthalmitis and incision construction. Curr Opin Ophthalmol 17: 68-71.

  3. May WN, Castro-Combs J, Kashiwabuchi RT, Tattiyakul W, Qureshi-Said S, et al. (2013) Sutured clear corneal incision: wound apposition and permeability to bacterial-sized particles. Cornea 32: 319-325.

  4. Kashiwabuchi FK, Khan YA, Rodrigues MW Jr, Wang J, McDonnell PJ, et al. (2013) Seidel and India ink tests assessment of different clear cornea side-port incision configurations. Graefes Arch Clin Exp Ophthalmol 251: 1961-1965.

  5. Srinivasan R, Tiroumal S, Kanungo R, Natarajan MK (2002) Microbial contamination of the anterior chamber during phacoemulsification. J Cataract Refract Surg 28: 2173-2176.

  6. McDonnell PJ, Taban M, Sarayba M, Rao B, Zhang J, et al. (2003) Dynamic morphology of clear corneal cataract incisions. Ophthalmology 110: 2342-2348.

  7. Chee SP (2005) Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%. Int Ophthalmol 26: 175-179.

Go to top
International Journal of Anesthetics and Anesthesiology (ISSN: 2377-4630)
International Journal of Blood Research and Disorders   (ISSN: 2469-5696)
International Journal of Brain Disorders and Treatment (ISSN: 2469-5866)
International Journal of Cancer and Clinical Research (ISSN: 2378-3419)
International Journal of Clinical Cardiology (ISSN: 2469-5696)
Journal of Clinical Gastroenterology and Treatment (ISSN: 2469-584X)
Clinical Medical Reviews and Case Reports (ISSN: 2378-3656)
Journal of Dermatology Research and Therapy (ISSN: 2469-5750)
International Journal of Diabetes and Clinical Research (ISSN: 2377-3634)
Journal of Family Medicine and Disease Prevention (ISSN: 2469-5793)
Journal of Genetics and Genome Research (ISSN: 2378-3648)
Journal of Geriatric Medicine and Gerontology (ISSN: 2469-5858)
International Journal of Immunology and Immunotherapy (ISSN: 2378-3672)
International Journal of Medical Nano Research (ISSN: 2378-3664)
International Journal of Neurology and Neurotherapy (ISSN: 2378-3001)
International Archives of Nursing and Health Care (ISSN: 2469-5823)
International Journal of Ophthalmology and Clinical Research (ISSN: 2378-346X)
International Journal of Oral and Dental Health (ISSN: 2469-5734)
International Journal of Pathology and Clinical Research (ISSN: 2469-5807)
International Journal of Pediatric Research (ISSN: 2469-5769)
International Journal of Respiratory and Pulmonary Medicine (ISSN: 2378-3516)
Journal of Rheumatic Diseases and Treatment (ISSN: 2469-5726)
International Journal of Sports and Exercise Medicine (ISSN: 2469-5718)
International Journal of Stem Cell Research & Therapy (ISSN: 2469-570X)
International Journal of Surgery Research and Practice (ISSN: 2378-3397)
Trauma Cases and Reviews (ISSN: 2469-5777)
International Archives of Urology and Complications (ISSN: 2469-5742)
International Journal of Virology and AIDS (ISSN: 2469-567X)
More Journals

Contact Us

ClinMed International Library | Science Resource Online LLC
3511 Silverside Road, Suite 105, Wilmington, DE 19810, USA
Email: contact@clinmedlib.org
 

Feedback

Get Email alerts
 
Creative Commons License
Open Access
by ClinMed International Library is licensed under a Creative Commons Attribution 4.0 International License based on a work at https://clinmedjournals.org/.
Copyright © 2017 ClinMed International Library. All Rights Reserved.